Multi-Channel TL-260 WIFI data logger with universal inputs is the perfect solutions for industrial and automation applications.
Features:
- 8-Universal Analog Inputs (Thermocouples, V, mV, mA, PT100)
- 2-Digital Inputs
- USB PC Interface
- WIFI Support
- High Accuracy
- Optional ISO-17025 accredited calibration certificate.
- 16/24 Bit Resolution
- Remote Monitoring
- Internal Memory with External Micro SD support
- Programmable High and Low Alarms
- Real Time Data View & Charting in Software
- Alarm Display on LCD
TL-260 WIFI data logger with universal inputs is the perfect solutions for industrial and automation applications.
TL-260 analog inputs are configurable to measure voltage, current, Pt100 & Thermocouples, also digital channels can be used to detect pulse changes and frequency measurements.
Daloco software is used for data read out, device configuration, reading real time values and live charting.
Measured signal values automatically convert to engineering units as user configuration.
Device Supports TCP/IP connection for monitoring on local networks and also can be setup to the Teknologg cloud servers for remote monitoring.
The Smart Logg mobile application is Teknologg another product which is used to receive data by using TCP/IP connection or cloud service.
General Parameters:
Channel Numbers | 8-Analog inputs, 2-Digital inputs |
Analog Inputs | DC Current: 0~24 ma DC Voltage: Class A: 0~ 10 V Class B: 0~ 5 V PT100-Thermocouple |
Conversion Resolution | Class A: 24-Bit Class B: 16-Bit |
Digital Inputs | Pulse Max 20VDC Frequency up to 10Khz |
sampling rate | Class A: 100 Hz Class B: 4 Hz |
LCD | 4-channel simultaneously Auto sweep |
Power | 12 ~ 24 VDC |
Memory | Internal:16000 Records External micro SD up to 32GB |
Record Time Interval | Class A:10 mili seconds ~ 24 hours Class B:250 mili seconds ~ 24 hours (configured by software) |
PC Interface | USB-B Port |
Working Temperature | -30 ~ 80°C Not for use in condensing conditions |
Dimensions | 157x99x45mm |
RTD | Characteristic |
---|---|
Probe Type | PT100 2-3-4 wire connection |
Resolution | 0.01 °C |
Accuracy | Typical 0.5°C |
Thermocouple Measuring | Characteristic |
---|---|
Probe Type | J,R,S,B,N,K,E,T |
Resolution | 0.1 °C |
Typical Accuracy | 0.5°C @ J,N,K,E,T 1.2°C @ R,S,B Check more detail on the data sheet |
WIFI Characteristics
Frequency | 2.4GHz EEE802.11b/g/n |
Output Power | +20dbm for 11b mode |
Receiver Sensitivity | -94 dBm |
WIFI Modes | Station/SoftAP |
TL-260.20 Multi-Channel WIFI Data Logger
Product No. | Details |
---|---|
TL-260.20A | Multi-Channel WIFI Data Logger Class A with USB Interface |
TL-260.20B | Multi-Channel WIFI Data Logger Class B with USB Interface |