Multi-Channel TL-260 data logger with universal inputs is the perfect solutions for industrial and automation applications.
Features:
- Universal Analog Inputs (Thermocouples, V, mV, mA, Pt100)
- USB PC Interface
- High Accuracy
- Optional ISO-17025 accredited calibration certificate.
- 16/24 Bit Resolution
- Optional Interfaces for RS232/RS485/GSM modem
- Internal Memory with External Micro SD support
- Programmable High and Low Alarms
- Real Time Data View & Charting in Software
- Alarm Display on LCD
TL-260 data logger with universal inputs is the perfect solutions for industrial and automation applications.
TL-260 analog inputs are configurable to measure voltage, current, Pt100 & Thermocouples, also digital channels can be used to detect pulse changes and frequency measurements.
Daloco software is used for data read out, device configuration, reading real time values and live charting.
Measured signal values automatically convert to engineering units as user configuration.
Optional Serial interfaces (RS485 Modbus, RS232 General, RS232 for GSM modem support) are available for ordering. The model with GSM modem support can connect to the Teknologg cloud servers for remote monitoring.
The Smart Logg mobile application is used to visualize data on cloud.
General Parameters:
Channel Numbers 8-Analog inputs, 2-Digital inputs
Analog Inputs DC Current: 0~24 ma
DC Voltage: Class A: 0~ 10 V Class B: 0~ 5 V
PT100-Thermocouple
Conversion Resolution Class A: 24-Bit
Class B: 16-Bit
Digital Inputs Pulse Max 20VDC
Frequency up to 10Khz
sampling rate Class A: 100 Hz
Class B: 4 Hz
LCD 4-channel simultaneously Auto sweep
Power 12 ~ 24 VDC
Memory Internal:16000 Records
External micro SD up to 32GB
Record Time Interval Class A:10 mili seconds ~ 24 hours
Class B:250 mili seconds ~ 24 hours
(configured by software)
PC Interface USB-B Port
Serial Interface TL-260.10: –
TL-260.11: RS485 Modbus
TL-260.12: RS232 General
TL-260.13: RS232 GSM Modem
Working Temperature -30 ~ 80°C
Not for use in condensing conditions
Dimensions 157x99x45mm
RTD Characteristic
Probe Type PT100
2-3-4 wire connection
Resolution 0.01 °C
Accuracy Typical 0.5°C
Thermocouple Measuring Characteristic
Probe Type J,R,S,B,N,K,E,T
Resolution 0.1 °C
Typical Accuracy 0.5°C @ J,N,K,E,T
1.2°C @ R,S,B
Check more detail on the data sheet
TL-260.1x Multi-Channel Data Logger
Product No. | Details |
---|---|
TL-260.10A/B | Multi-Channel Data Logger Class A/B with USB Interface |
TL-260.11A/B | Multi-Channel Data Logger Class A/B with USB Interface and RS485 Modbus |
TL-260.12A/B | Multi-Channel Data Logger Class A/B with USB Interface and General RS232 |
TL-260.13A/B | Multi-Channel Data Logger Class A/B with USB Interface and RS232 for GSM Modem interface |